teakdeck & touchscreen
Error codes · VOLT & MUST

Fault 32, every evening on the dot.

MUST off-grid inverters, sold in Poland as VOLT Sinus Pro, are fitted in many houseboats. They show faults as a number on the display, and the list that explains them is somewhere in the manual. Here it is in words, with what we have seen on board.

Side mirror of the houseboat reflecting the sunset
Sunset. Fault 32 is about to report in.

These units combine inverter, mains charger and solar charger in one box, so the list mixes faults from all three parts. Codes 31 to 33 and 72 to 77 concern the built-in solar charger, 41 to 44 the shore power.

One experience first: on a houseboat we look after, the inverter reported fault 32 every evening at sunset for days and withdrew it at sunrise. Without light the solar charger measures no current and takes that for a sensor fault. Since then our display logs it as harmless instead of raising the alarm twice a day.

How to read the list: usually harmless clears by itself or is a warning, check yourself is something you can look at on board without opening anything, electrician belongs with someone qualified to work on 230 volts.

1 2 3 4 5 6 7 8 9 11 21–25 26 27 31 32 33 41–44 51 52 53 55 56 57 58 61/62 63 64 67 70 72 73 74 75 76 77

Error 1 · Fan blocked, inverter off check yourself

Dust, a cable tie, a bit of packaging. Look with the unit switched off.

Error 2 · Transformer too hot check yourself

Too much load for too long, or too little air where it is fitted.

Error 3 · Battery voltage too high check yourself

Is a second device charging too, such as the alternator or another solar controller?

Error 4 · Battery voltage too low check yourself

The battery is flat or a heavy load is dragging it down. Charge it and reduce the load.

Error 5 · Short circuit on the output electrician

An appliance or cable on the 230-volt output is short-circuited. Unplug appliances, then call a professional.

Error 6 · Output voltage too high electrician

One for the workshop.

Error 7 · Overload for too long check yourself

Kettle, hair dryer and fan heater at once are too much for many units. Switch fewer on together.

Error 8 · Internal bus voltage too high electrician

Concerns the internal DC bus. Workshop.

Error 9 · Internal soft start failed electrician

Workshop.

Error 11 · Main relay faulty electrician

The unit can’t switch cleanly between shore power and battery. Workshop.

Error 21–25 · Sensor fault electrician

One of the internal voltage or current measurements is giving nonsense. Workshop.

Error 26 · Over-current from shore power check yourself

Charging plus loads draw more than allowed. Reduce charge current or load.

Error 27 · Heat sink too hot check yourself

Give it air, reduce the load.

Error 31 · Solar charger: wrong battery voltage class electrician

Unit and battery don’t match in nominal voltage.

Error 32 · Solar charger: current sensor usually harmless

If it comes in the evening and goes in the morning, it’s the behaviour without light described above and harmless. During the day in sunshine it would be a real fault for the workshop.

Error 33 · Solar charger: current out of control electrician

Workshop.

Error 41–44 · Shore power: voltage or frequency out of range usually harmless

On a busy pontoon or a generator the shore power fluctuates. The unit then disconnects and runs the boat from the battery. If it happens a lot, ask the marina or use a cable with a larger cross-section.

Error 51 · Inverter over-current protection check yourself

An appliance with a high start-up current, such as a compressor. Switch things on one after another.

Error 52 · Internal bus voltage too low electrician

Workshop.

Error 53 · Inverter soft start failed electrician

Workshop.

Error 55 · DC voltage on the 230-volt output electrician

Workshop, and until then don’t plug in sensitive appliances.

Error 56 · Battery not connected check yourself

On boats often very simple: the battery main switch is off or a fuse has blown.

Error 57 · Control current sensor fault electrician

Workshop.

Error 58 · Output voltage too low check yourself

Usually overload or a weak battery. Reduce the load, charge.

Error 61/62 · Fan blocked check yourself

Like fault 1, as a warning. The second fan reports as 62.

Error 63 · Battery over-charged check yourself

Have the charge voltages checked, and whether a second charger is also charging.

Error 64 · Battery low usually harmless

A warning before fault 4 arrives. Charge or reduce consumption.

Error 67 · Overload check yourself

Warning before fault 7. Switch one appliance off.

Error 70 · Output reduced usually harmless

The unit protects itself from heat by delivering less. Normal in a tight cupboard in summer.

Error 72 · Solar charger off: battery too low check yourself

The battery is so deeply discharged that the solar charger won’t start. Top it up with shore power.

Error 73 · Solar charger off: panel voltage too high check yourself

As with all solar chargers, highest on cold, clear mornings. Have the wiring checked.

Error 74 · Solar charger off: overload check yourself

Reduce the load and it starts again.

Error 75 · Solar charger too hot check yourself

Give it air.

Error 76 · Communication fault with the solar charger electrician

An internal connection in the unit. Workshop.

Error 77 · Parameter error electrician

The stored settings are inconsistent. Have them set up again.

An inverter carries 230 volts even without shore power. Anything beyond switches, the app and a visual check belongs with a qualified workshop. Your device’s manual always takes precedence.

Where we come in

We don’t repair inverters or charge controllers, that is a job for a qualified workshop. What we do is make sure a code doesn’t go unnoticed until your next visit: it appears in plain words on your phone, together with what belongs to it, battery, shore power and temperature, and the logbook shows when it came and when it went. Then it’s quickly clear whether it can wait until the weekend.

This is what the display looks like, and this is what set-up costs. If you prefer, we organise the fitting of any missing parts.

Frequently asked questions

Is the VOLT Sinus Pro the same as the MUST PV1800?

In our experience yes, identical inside, with the same fault codes. Your unit’s label and manual still take precedence.

Fault 32 appears every evening, do I need to do anything?

If it comes at sunset and goes at sunrise, no. Without light the solar charger measures no current. During the day in sunshine it should be taken seriously.

Can I see the faults remotely?

The units have a data port through which readings and faults can be read without changing anything. That’s how we set it up: the code appears in plain words on your phone and in the logbook.

Victron Energy, MultiPlus, Quattro, SmartSolar, BlueSolar, Skylla and Orion are trademarks of Victron Energy B.V.; MUST and VOLT belong to their respective owners. We are independent and not affiliated with any of the manufacturers.

More error codes: Victron MultiPlus · Victron solar charger · Guides: Victron Cerbo GX installation and set-up · Bilge alarm on your phone · Internet on a boat · Boat monitoring compared

A first conversation

We come on board.

In Dutch Friesland and north-west Germany. After the first visit you’ll know:

  • what your boat can already show today,
  • what a wish still needs,
  • and what it costs.
Write to us

Ideally with the type of boat and mooring, or straight on WhatsApp. We speak English, Dutch and German.