Error codes · Victron MultiPlus & Quattro

When the MultiPlus shows a number.

The red light is flashing, the app says “VE.Bus Error 11”, and the manual offers three lines of English. Here is what the codes mean on board, which ones are harmless and when it’s better to call someone.

Helm of a trawler in the evening: tablet and plotter on teak, sunset over the water behind
A code in the evening doesn’t have to wait until morning.

MultiPlus, Quattro and the older Phoenix inverters talk to each other and to the Cerbo over their own data cable, the VE.Bus. Whatever goes wrong there is reported as a “VE.Bus Error” with a number, in the VictronConnect app, on the Cerbo and in the VRM portal. Many of these errors only concern systems with several units; on a boat with a single MultiPlus you usually only ever see a handful.

One tip first, which Victron gives too: home-crimped network cables between the units are one of the most common causes of the errors on this list. Ready-made cables are cheap and save a lot of searching.

How to read the list: usually harmless clears by itself or is a warning, check yourself is something you can look at on board without opening anything, electrician belongs with someone qualified to work on 230 volts.

1 2 3 4 5 6 7 8 10 11 12 14 15 16 17 18 19 20 22 24 25 26 30/31 128

Error 1 · Another unit in the system has switched off check yourself

Only with several units. The others are simply reporting that one is missing. The real cause shows on the unit that is not displaying this code, usually overload, a flat battery or heat. Restarts by itself once the cause has gone.

Error 2 · Old and new generation units mixed electrician

According to the manufacturer this should never happen. One for the Victron dealer. Restarts by itself once the cause has gone.

Error 3 · Not all expected units found electrician

Often follows error 1. Otherwise a data cable, a wrong configuration or a blown DC fuse in one unit, which only shows once shore power is gone. Restarts by itself once the cause has gone.

Error 4 · No other unit found usually harmless

Perfectly normal for a moment during a restart. If it stays, a data cable is the usual suspect. Restarts by itself once the cause has gone.

Error 5 · Overvoltage on the AC output electrician

Usually the AC wiring of one of the slave units is missing or wrongly connected. Restarts by itself once the cause has gone.

Error 6 · Error in an Assistant electrician

The small add-on programs in the unit don’t match the firmware or the system, for example after a battery management system was connected or removed. Fixed with new firmware and reconfiguration. Restarts by itself once the cause has gone.

Error 7 · External device connected, Assistant missing electrician

A battery management system or similar is on the bus, but the matching program hasn’t been set up. Restarts by itself once the cause has gone.

Error 8 · Ground relay test failed electrician

MultiPlus-II and EasySolar-II test their ground relay continuously. Causes range from the neutral and earth wiring to an appliance leaking current to a faulty relay. Restarts by itself once the cause has gone.

Error 10 · Time synchronisation problem usually harmless

Appears during a restart and is then not an error in itself. What matters is what came before it in the log, often error 1. Restarts by itself once the cause has gone.

Error 11 · Relay test failed electrician

The MultiPlus-II tests its relays before connecting to shore power. Usually the installation is behind it: live and neutral swapped, earthing, an appliance leaking current. Less often a relay is faulty. It shows up more often on pontoons with poor shore power. Restarts by itself once the cause has gone.

Error 12 · Settings mismatch between the two processors electrician

Rare. The settings need to be sent to the unit again in full. Restarts by itself once the cause has gone.

Error 14 · Unit cannot transmit data electrician

Usually a short in a data cable, very occasionally a component inside the unit. Restarts by itself once the cause has gone.

Error 15 · Incompatible combination electrician

Units or firmware versions don’t match. Updating all units usually solves it. Restarts by itself once the cause has gone.

Error 16 · VE.Bus dongle missing electrician

A leftover from old firmware. After an update the dongle is no longer needed. Stays off until the system is restarted.

Error 17 · Phase master missing electrician

Only with several units per phase. Usually cables or sockets, sometimes a blown DC fuse. Restarts by itself once the cause has gone.

Error 18 · Voltage on the output of a slave that is switched off electrician

There should never be voltage on the output of a unit that is off. AC wires have probably been swapped. Stays off until the system is restarted.

Error 19 · Slave has no AC input electrician

Typical when a generator or shore power feeds only one of several units. Either connect them all or change the configuration. Stays off until the system is restarted.

Error 20 · Configuration mismatch electrician

Extended options are switched on while a grid code is selected, and the two don’t go together. Stays off until the system is restarted.

Error 22 · Unit cannot act as a slave electrician

An outdated model that cannot take part in this set-up. Stays off until the system is restarted.

Error 24 · Switch-over protection triggered electrician

Current flowed through the shore power relay while it should have been open. Most common cause: too much load at the moment of switching, or generator or pontoon voltage sagging slowly. Switching off big loads during the changeover helps. Stays off until the system is restarted.

Error 25 · Incompatible system configuration electrician

Different firmware, or units which according to their labels may not be run together. Stays off until the system is restarted.

Error 26 · Internal error check yourself

Switch everything off and on again and the system usually carries on. If it comes back, see the dealer. Stays off until the system is restarted.

Error 30/31 · Ghost errors usually harmless

A corrupted message on the data cable. The odd one is harmless; if they pile up, have the cables and plugs checked.

Error 128 · Connection to the grid prevented electrician

On the Quattro-II the relay test keeps failing for more than five minutes, so the unit won’t connect to shore power.

An inverter carries 230 volts even without shore power. Anything beyond switches, the app and a visual check belongs with a qualified workshop. Your device’s manual always takes precedence.

Where we come in

We don’t repair inverters or charge controllers, that is a job for a qualified workshop. What we do is make sure a code doesn’t go unnoticed until your next visit: it appears in plain words on your phone, together with what belongs to it, battery, shore power and temperature, and the logbook shows when it came and when it went. Then it’s quickly clear whether it can wait until the weekend.

This is what the display looks like, and this is what set-up costs. If you prefer, we organise the fitting of any missing parts.

Frequently asked questions

Where do I see the VE.Bus error code?

In the VictronConnect app, on the Cerbo GX or the control panel under the inverter, and in the VRM portal if the system is online. The unit itself only shows flashing lights.

Can I simply switch the MultiPlus off and on again?

Yes, with the switch on the front of the unit, and one after the other if there are several. Many errors clear that way, though not always their cause. Note the code down first.

Which errors are most common on a boat?

With a single MultiPlus mainly errors 8 and 11 around earthing and shore power, plus overload and a flat battery, which appear as warning lights rather than codes.

In full detail from the manufacturer: www.victronenergy.com/live/ve.bus:ve.bus_error_codes.

Victron Energy, MultiPlus, Quattro, SmartSolar, BlueSolar, Skylla and Orion are trademarks of Victron Energy B.V.; MUST and VOLT belong to their respective owners. We are independent and not affiliated with any of the manufacturers.

More error codes: Victron solar charger · VOLT / MUST · Guides: Victron Cerbo GX installation and set-up · Bilge alarm on your phone · Internet on a boat · Boat monitoring compared