teakdeck & touchscreen
Error codes · Victron solar charger

The solar charger rarely speaks up without a reason.

SmartSolar and BlueSolar chargers usually work away quietly for years. When “Err 38” or “Err 67” then appears in the app, you want to know whether the battery is at risk or whether it can wait until the weekend.

View from the covered foredeck over calm water
Above the roof the sun is at work, mostly in silence.

The list applies to all Victron MPPT solar chargers, to the Skylla mains chargers and to the Orion Smart DC-DC chargers between starter and house battery. The codes appear in the VictronConnect app, on the Cerbo and on the small display where one is fitted. Codes that only concern the large RS inverters have been left out.

How to read the list: usually harmless clears by itself or is a warning, check yourself is something you can look at on board without opening anything, electrician belongs with someone qualified to work on 230 volts.

1 2 3/4 5 6/7 8 14 17 18 20 21 22/23 24 26 27 28 29 33 34 38/39 40 65 66 67 68 114 116 117 119 121

Err 1 · Battery too hot usually harmless

The charger pauses until the battery has cooled down, which protects it. Restarts by itself once the cause has gone.

Err 2 · Battery voltage too high check yourself

Often another device is charging the battery higher, such as the mains charger or the alternator, or the system voltage in the charger is set too low. Restarts by itself once the cause has gone.

Err 3/4 · Temperature sensor wired wrongly electrician

Usually the sensor is connected to the positive or negative terminal instead of its own input. Restarts by itself once the cause has gone.

Err 5 · Temperature sensor connection lost check yourself

A plug has come loose or a wire is off. A look is often enough. Stays off until the system is restarted.

Err 6/7 · Voltage sense wired in reverse electrician

The thin sense wires to the battery are connected the wrong way round.

Err 8 · Voltage sense connection lost check yourself

A loose sense wire at the battery, often after work in the battery box.

Err 14 · Battery too cold usually harmless

Lithium batteries must not be charged below freezing, so the charger waits. Perfectly normal in winter storage. Restarts by itself once the cause has gone.

Err 17 · Charger overheated check yourself

Too hot despite reduced output. Is there enough air around the unit, or is something lying on the heat sink? Restarts by itself once the cause has gone.

Err 18 · Over-current usually harmless

A large load was switched or the sun burst out from behind a cloud. Resets itself; otherwise disconnect power for three minutes. Restarts by itself once the cause has gone.

Err 20 · Maximum bulk time exceeded check yourself

On old solar chargers a firmware leftover that an update removes. On a Skylla it means the battery hasn’t reached charge voltage after ten hours, possibly a faulty cell.

Err 21 · Current sensor electrician

The current measurement is out of range. Have all wires disconnected and reconnected once; if it stays, the unit is one for the dealer. Stays off until the system is restarted.

Err 22/23 · Internal temperature sensor electrician

As with Err 21: reconnect, otherwise the dealer. Stays off until the system is restarted.

Err 24 · Fan electrician

Skylla chargers only: the fan draws no current, so it is blocked or broken.

Err 26 · Terminals overheated electrician

Take it seriously even if it clears by itself: loose screws or undersized cables get hot at the terminal. Restarts by itself once the cause has gone.

Err 27 · Short circuit on the charger output check yourself

Can occur when connecting through a relay. If it persists, disconnect power for three minutes; if it returns, the charger is probably faulty. Restarts by itself once the cause has gone.

Err 28 · Power stage electrician

If it remains after reconnecting, the charger needs replacing. Stays off until the system is restarted.

Err 29 · Over-charge protection check yourself

The charger disconnects the battery to protect it. Often another device is charging too, or the charge voltages don’t suit the battery. Restarts by itself once the cause has gone.

Err 33 · Solar panel voltage too high check yourself

On clear, cold winter mornings solar panels deliver more voltage than in summer. If it appears then, too many panels are wired in series. Have the wiring checked before the charger is damaged. Restarts by itself once the cause has gone.

Err 34 · Solar panel current too high electrician

Disconnect power for three minutes. If it stays, the charger is probably faulty.

Err 38/39 · Solar input shorted for protection check yourself

The charger protects the battery from over-charging. Typically the system voltage is set wrongly, or another device, such as the MultiPlus during equalisation, pushes the voltage up. Err 39 clears by itself; Err 38 needs panels off, battery off, three minutes’ wait, then battery first and panels after. Also Err 80 to 87.

Err 40 · Solar input failed to shut down electrician

The charger goes into a safe state and stops charging. It is then faulty.

Err 65 · Notice: connection to a paralleled charger lost usually harmless

Several chargers coordinate and one has dropped out briefly. Switching off and on clears the notice.

Err 66 · Notice: incompatible chargers check yourself

Two chargers have different settings, or they are trying to coordinate over Bluetooth while the Cerbo already does so. Switch one of the two off.

Err 67 · BMS connection lost check yourself

Typical pattern: appears in the morning as soon as there is sun and goes in the evening. The charger is waiting for permission from the lithium battery and not getting it. If the charger came from another system, that setting has to be reset.

Err 68 · Network misconfigured electrician

The charger is connected by both a VE.Direct and a VE.Can cable. Unplug one of them, or the firmware is out of date.

Err 114 · CPU too hot check yourself

Are the vents clear? Has the cupboard been filled up? Resets once cooled. Restarts by itself once the cause has gone.

Err 116 · Calibration data lost usually harmless

If it only shows in the history and the charger is working, it’s an old factory entry. If it’s active and the charger has stopped, the unit is faulty.

Err 117 · Incomplete firmware check yourself

An update was interrupted, for instance because the phone was too far away. Repeat the update calmly.

Err 119 · Settings lost electrician

The charger has lost its settings and stopped. Factory reset, reconfigure, and report it to the dealer. Stays off until the system is restarted.

Err 121 · Factory test usually harmless

As with Err 116: harmless in the history only, a fault when active.

An inverter carries 230 volts even without shore power. Anything beyond switches, the app and a visual check belongs with a qualified workshop. Your device’s manual always takes precedence.

Where we come in

We don’t repair inverters or charge controllers, that is a job for a qualified workshop. What we do is make sure a code doesn’t go unnoticed until your next visit: it appears in plain words on your phone, together with what belongs to it, battery, shore power and temperature, and the logbook shows when it came and when it went. Then it’s quickly clear whether it can wait until the weekend.

This is what the display looks like, and this is what set-up costs. If you prefer, we organise the fitting of any missing parts.

Frequently asked questions

My solar charger shows Err 67 every morning, is the battery at risk?

No, rather the opposite: the charger isn’t charging because it has no permission from the battery management system. But that also means the sun isn’t charging the battery, so the connection should be checked soon.

Why does Err 33 only appear in winter?

Cold solar panels deliver more voltage. What just fits in summer is too much for the charger on a frosty, sunny morning.

Where can I see which error is active?

In VictronConnect on the charger’s main page; the history also shows older errors from the last 30 days. On the Cerbo under the solar charger.

In full detail from the manufacturer: www.victronenergy.com/live/mppt-error-codes.

Victron Energy, MultiPlus, Quattro, SmartSolar, BlueSolar, Skylla and Orion are trademarks of Victron Energy B.V.; MUST and VOLT belong to their respective owners. We are independent and not affiliated with any of the manufacturers.

More error codes: Victron MultiPlus · VOLT / MUST · Guides: Victron Cerbo GX installation and set-up · Bilge alarm on your phone · Internet on a boat · Boat monitoring compared

A first conversation

We come on board.

In Dutch Friesland and north-west Germany. After the first visit you’ll know:

  • what your boat can already show today,
  • what a wish still needs,
  • and what it costs.
Write to us